SKU: #HV-49-RPD-A-0.5-9.5-R-ST

REFRIGERANT RECOVERY AND FILLING DEVICE PRO DIGITAL

Precio de oferta
5.0

Tool Description

Optimize Your Refrigerant Recovery with Our High-Efficiency Lightweight Unit

Introducing our state-of-the-art Lightweight Recovery Unit, engineered for the effective recovery of refrigerants across classes A1, A2L, and A2, including R32. Designed for HVAC professionals, this unit combines a high recovery rate with a user-friendly, maintenance-free operation, making it suitable for all unit sizes.

Application Benefits 

  • Durable 4-Pole Motor: Ensures the long-lasting reliability of the unit, providing peace of mind for continuous operation.
  • Low Noise and Vibration: The compact design minimizes noise and vibration emissions, making it ideal for use in noise-sensitive environments.
  • Intuitive Operation: Designed with simplicity in mind, the unit offers safe and straightforward handling for all users, regardless of experience level.
  • Maintenance-Free: Thanks to the oil-free compressor, enjoy hassle-free operation without the need for regular maintenance.
  • Versatile PURGE Function: Easily switch between different refrigerants with the unit's PURGE function, ensuring clean and efficient recovery every time.
  • Portable Design: The lightweight and compact plastic casing makes it easy to transport and use the unit wherever needed, enhancing its versatility.
  • Rapid Recovery Rates: Offers gaseous recovery at 0.5 kg/min, liquid at 3.5 kg/min, and push/pull at 9.5 kg/min, ensuring efficient operation for various system sizes.
  • Power and Compatibility: With a 730 W power output and a 230 V / 50–60 Hz power supply, it's ready for diverse operational settings.
  • Safety Features: Includes a high-pressure switch set at 38.5 bar, providing additional safety and reliability during use.
  • Power supply    230V.    60Hz
    Power
    730W
    High pressure switch
    38.5 bar
    Refrigerant Recovery of refrigerant of the classes A1,A2L & A2 including R32
    Recovery rate

    ..Gaseous 0,5 kg/min (R410A)

    Liquid: 3,5 kg/min (R410A) Push/Pull: 9,5 kg/min (R410A)

Key Product Features & Benefits


Feature Description Digital display Low pressure switch Oil free 2 piston compressor

Practical storage compartment

Benefits
 Clearly structured display of the measured pressure values

Automatic shut off and automatic restart once the pressure increases again 

 

Very high recovery rate with maintenance free operations

 

Can store accessories in the back


 

Product Videos

FEATURES

High Recovery Rate

The unit boasts impressive recovery rates, with capabilities such as 0.5 kg/min for gaseous states, 3.5 kg/min for liquid refrigerants, and an accelerated 9.5 kg/min rate in push/pull mode, making it suitable for all unit sizes and ensuring quick recovery processes.

4-Pole Motor

Equipped with a durable 4-pole motor, the recovery unit guarantees long-lasting performance and reliability, even in the most demanding conditions, ensuring the machine's longevity.

Low Noise and Vibration

Thanks to its compact design, the unit operates with minimal noise and vibration emissions, making it suitable for use in noise-sensitive environments like residential areas or hospitals.

Intuitive Handling

Designed for ease of use, the unit features intuitive controls that simplify its operation, making it accessible for both experienced technicians and those new to refrigerant recovery tasks.

Maintenance-Free Operation

The oil-free compressor within the unit requires no regular maintenance, reducing downtime and operational costs, and ensuring hassle-free performance.

PURGE Function

An integrated PURGE function allows for the easy emptying of the device to switch between different refrigerants without cross-contamination, enhancing the unit's versatility across various HVAC applications.

Lightweight and Compact Design

Housed in a light and compact plastic casing, the recovery unit is easy to transport and use in various locations, from tight residential spaces to commercial buildings.

Safety Features

The unit is equipped with a high-pressure switch set at 38.5 bar to protect the system and operator from over-pressurization, ensuring safe usage under all conditions.

Power Supply and Consumption

With a power supply requirement of 230 V / 50–60 Hz and a power consumption of 730 W, the unit is designed for energy-efficient operation without compromising on performance.

Standard and Adaptable Connections

It comes standard with a 1/4" SAE connection and includes adaptors for 5/16" SAE and 3/8" SAE, offering compatibility with a wide range of HVAC systems and ensuring broad applicability.

APPLICATIONS

Refrigerant Recovery in HVAC Systems

The unit is ideal for recovering refrigerants from air conditioning systems, heat pumps, and refrigeration units during maintenance, repair, or decommissioning. Its compatibility with various refrigerant classes ensures broad applicability across different HVAC systems.

HVAC System Decommissioning

When HVAC systems are being replaced or decommissioned, the recovery unit plays a crucial role in safely removing and recovering the refrigerant from the system, ensuring that it can be recycled or disposed of in accordance with environmental regulations.

System Repairs and Leak Testing

Before conducting repairs or leak testing on HVAC systems, it's necessary to recover the existing refrigerant. This unit allows for efficient refrigerant removal, enabling safe access to system components for repairs or testing.

Conversion and Retrofitting Projects

For systems undergoing conversion to different refrigerant types or retrofitting for improved efficiency or environmental compliance, the recovery unit facilitates the removal of the old refrigerant, making way for the new refrigerant type.

Routine Maintenance and Servicing

During routine maintenance, the recovery unit can be used to temporarily remove refrigerant from specific system parts, allowing for cleaning, inspection, and servicing without system-wide refrigerant loss.

Emergency Leak Response

In cases where refrigerant leaks pose safety or environmental hazards, the recovery unit allows for rapid removal of refrigerant from the compromised system, mitigating potential risks and facilitating repair work.

HVAC Training and Education

In educational settings, the recovery unit serves as a practical tool for training HVAC technicians in the proper methods of refrigerant recovery, handling, and environmental compliance, preparing them for fieldwork.


Cross-Product Recommendations

Agotado
TWO STAGE VACUUM PUMP - 1.5CFM / (42L/MIN)TWO STAGE VACUUM PUMP - 1.5CFM / (42L/MIN)
TWO STAGE VACUUM PUMP - 3.0CFM / (85L/MIN)TWO STAGE VACUUM PUMP - 3.0CFM / (85L/MIN)
REFRIGERANT PRESSURE HOSE SETS - STANDARD SERIES
TWO STAGE VACUUM PUMP - 6.0CFM / (170L/MIN)
TWO STAGE VACUUM PUMP - 9.0CFM / (255L/MIN)

Disclaimer for Product Reviews

K&T JV does not assume responsibility for, nor does it endorse, the content of any posted product review or statement. The statements expressed belong solely to the poster and do not reflect the views of K&T JV. K&T JV does not make any assurances regarding the appropriateness, accuracy, completeness, correctness, currentness, suitability, or validity of the product reviews or statements, even those posted by K&T JV Ltd employees. The company is not accountable for any losses, injuries, or damages that may arise from such product reviews or statements. Users engage with any linked website provided in a product review or post at their own risk. For further details, please refer to the Terms and Conditions.

Sample Text with Icons

Free shipping

Free worldwide shipping and returns - customs and duties taxes included

Customer service

We are available from monday to friday to answer your questions.

Secure payment

Your payment information is processed securely.